Monitor and Log Hospital Rooms
A negative pressure isolation room’s purpose is to prevent contamination threats to other areas. Ill-fitting doors, HVAC failure and human error are just a few of the reasons attributed to contaminated air breeches. To protect your workers and greatly reduce the possibility of air contamination you need the TV2 differential pressure monitor.
Many hospitals use the ball-in-the-wall device. Read Blog Post on using ball-in-the-wall for Covid safety.
This is not a good idea. It can only indiate that one room has a negative pressure or not. It has no way to monitor multiple rooms, send text or email alerts if the pressure suddenly becomes positive. And it can not be accessed remotely. The TV2 Negative Pressure Monitor has all of these features and more.
The TV2 Hospital Room Pressure Monitor can accurately report pressure conditions in multiple isolation rooms for:
- Additional sensors can be added to the TV2 hospital room monitor.
- Additional temperature and Relative Humidity sensors can be added.
- All pressure sensors can be used for positive and negative pressure areas.
- Hospital Room monitor can also be used for Cleanrooms and Pharmacy areas.
The TV2 Hospital Room Monitor meets all Federal Requirements
ISO 1 Cleanroom | ISO 2 Cleanroom | ISO 3 Cleanroom |
ISO 4 Cleanroom | ISO 5 Cleanroom | ISO 6 Cleanroom |
ISO 7 Cleanroom | ISO 8 Cleanroom | ISO 9 Cleanroom |
*Includes Class 1 Cleanroom, Class 2 Cleanroom, Class 3 Cleanroom, Class 4 Cleanroom
Specifications
Channels | 3 – Temp/RH and pressure |
QuickCheck Display | 1. Temperature (°F/C), Humidity (% RH) 2. Pressure (“WG) 3. Backup battery indication 4. Max/Min for each environmental variable 5. Alarm enabled/disabled 6. Date and time 7. Last time data reviewed |
Monitoring | QuickCheck Display Green text=safe Red text=unsafe |
Alerts |
|
Alarm Settings |
|
Sample Interval | Every 5 to 20 seconds |
Environmental Condition Range |
|
Employee Data Review | Button on QuickCheck display |
Calibration | Temperature/RH NIST Traceable Pressure (Auto Calibrate) |
Characterization | Three-point calibration table for each sensor |
Display Controls | Easy-Touch display responds to a finger touch |
Data Storage Technique | Non-volatile memory stores 80,000 samples per sensor |
Power | Via USB cable to PC or power adapter (90 to 240vac) |
Battery Backup |
|
Output to PC | USB cable (Note: if USB cable is plugged into PC, power is supplied by PC) Local Area Network via wired Ethernet or WiFi |
PC Software |
|
LCD Pixels` | 488 horizontal x 270 vertical |
Mounting | Wall or panel mount |
Display Weight | 1 pound |
User settings | Via Easy-Touch display |
LED Indicator | Green indicates AC power present |
Power Supply | UL listed |
Monitor | FCC and CE mark |
Environmental condition alerts | Visual indications: Green = safe Red =unsafe |
Data logging interval | Between 1/min and 1/day |